inquiry
zostaw wiadomość
Jeśli jesteś zainteresowany naszymi produktami i chcesz poznać więcej szczegółów, zostaw wiadomość tutaj, a my odpowiemy tak szybko, jak to możliwe.
składać
Bengbu Longkai Welding Protection Technology Co.,Ltd.
Dom

System respiratora powietrza zasilanego

System respiratora powietrza zasilanego

  • Why All NEW AIR PAPR Units Choose RILSA NB1024 for Certification?
    Why All NEW AIR PAPR Units Choose RILSA NB1024 for Certification?
    Jun 25, 2026
    As EU PPE regulations keep tightening and the updated EN12941:2023 & EN12942:2023 standards come into full force, the compliance threshold for powered air-purifying respirators (PAPR) exported to Europe has risen significantly. There are countless notified bodies across the EU with huge gaps in certification validity and testing capacity. Many manufacturers frequently face troubles including questioned certificates, suspended annual surveillance and customs detention.   As a professional manufacturer of papr air purifier protection equipment, NEW AIR sends our full product range to RILSA (Notified Body NB1024, Czech Republic) for certification consistently, without switching to other certification bodies. Our overseas customers also widely recognize CE certificates issued by NB1024. This consistent choice stems from five irreplaceable core strengths listed below. 1. Comprehensive Specialized RPD Qualifications to Prevent Certificate Invalidation   Registered in the EU NANDO database, RILSA NB1024 holds full official authorization for respiratory protective devices (RPD) under Regulation (EU) 2016/425. It is fully accredited to issue certificates against both core PAPR standards EN12941 and EN12942, with no risk of out-of-scope certification. RILSA runs its own ISO 17025 accredited laboratory No.1040. All mandatory tests for best papr respirator – total inward leakage, airflow stability, filter penetration, high-low temperature durability and more – are completed in-house without outsourcing to third-party labs. All test data is complete and fully traceable.   As a notified body qualified for full conformity assessment of Category III high-risk PPE, RILSA delivers Module B type examination plus Module C2 annual surveillance as a complete package. Most small notified bodies can only offer Module B testing without follow-up surveillance, which easily leads to expired or invalid certificates. This full-service model perfectly matches NEW AIR’s long-term mass export demands.   2. Endorsed by Industry Benchmark Brands, Highly Recognized by Buyers   Leading European welding equipment manufacturers and top local PPE brands have long relied on RILSA for PAPR certification, building outstanding industry credibility through thousands of successful projects.   Many overseas distributors and PPE purchasers explicitly require suppliers to provide products certified by RILSA. In buyers’ eyes, the NB1024 number is a symbol of rigorous, authoritative performance verification for respiratory protection. When comparing identical PAPR products, NEW AIR respirators carrying NB1024 certificates pass customer qualification reviews much faster and secure large-volume purchase orders, granting us a distinct competitive edge in global markets.   3. Smooth Customs Clearance & Stable Market Surveillance, Low Risk of Certificate Suspension or Revocation   RILSA is a state-owned national occupational safety research institute in the Czech Republic, not a purely commercial private certification body. It enjoys high credibility with EU customs authorities and market surveillance agencies across all member states.   Shipments with NB1024 certificates face far lower inspection rates at EU borders, avoiding extra detention fees and delivery delays caused by questioned certification credentials. In the event of random EU market surveillance audits, RILSA can supply full original test records with complete data trails. Cases of certificate suspension, revocation or forced product withdrawal are extremely rare, drastically cutting compliance risks for NEW AIR’s large-scale shipments.   4. Full Certification Capacity for EN12941:2023 & EN12942:2023 to Secure Long-Term Compliance   The latest standard revisions introduced stricter mandatory test items, including mercury and NOx filter performance, unified total inward leakage assessment, battery safety and extreme temperature cycling durability. RILSA participated in the drafting of EU respiratory protection standards and completed full capability expansion for both updated 2023 standards well in advance. It can certify NEW AIR’s core welding helmet-style PAPR as well as tight-fitting full/half mask PAPR for chemical applications. New product certification and legacy certificate upgrades can be processed in one stop, eliminating repeated testing fees and the hassle of switching notified bodies to maintain market access.   5. One-Stop Certification Service Aligned with Mass Production & Export Cycles   RILSA maintains mature, streamlined communication channels for Chinese papr respirators manufacturers. Its technical team is familiar with integrated welding PAPR structures, composite filter media and blower modules made in China, delivering practical, efficient corrective action guidance when adjustments are needed.   The full Module B + C2 certification timeline is predictable and stable. Annual surveillance mainly consists of online document reviews and small sample lab testing, removing the need for frequent on-site factory audits in Europe. Thanks to this low-maintenance certification framework, NEW AIR’s team can minimize time spent on compliance paperwork and focus more on product R&D and global market expansion.   NEW AIR consistently chooses RILSA NB1024 for our entire PAPR lineup not merely for balanced lead times and competitive costs, but as the optimal all-round solution covering legitimate accreditation, global buyer recognition, trouble-free customs clearance, up-to-date standard compliance and long-term certificate stability. This is the core reason why NB1024 certificates remain trusted by industrial purchasers worldwide.If you want know more, please click  www.newairsafety.com.
    CZYTAJ WIĘCEJ
  • BXH-3003 Supercienki plecak PAPR
    BXH-3003 Supercienki plecak PAPR
    Jun 01, 2026
    BXH-3003 to najnowszy PAPR firmy NEW AIR. Jest to główna jednostka dmuchawy o wysokiej wydajności Zasilany respirator oczyszczający powietrze , profesjonalny osobisty system ochrony dróg oddechowych zaprojektowany do użytku w środowiskach wysokiego ryzyka, takich jak zakłady przemysłowe i skażone miejsca pracy. Jako serce całego systemu, ten system PAPR aktywnie zasysa powietrze z otoczenia, oczyszcza je poprzez wielostopniową filtrację i dostarcza ciągły strumień czystego powietrza pod ciśnieniem dodatnim do maski twarzowej użytkownika. To nadciśnienie działa jak krytyczna bariera, zapobiegając przedostawaniu się zanieczyszczeń do układu oddechowego i tworząc solidną, niezawodną linię obrony dla użytkownika.Kluczową zaletą tego jest papier powietrzny Dmuchawa charakteryzuje się mocą i stabilnym przepływem powietrza. Posiada trzy regulowane poziomy przepływu powietrza, osiągając maksymalnie 130 l/min, co pozwala na dostosowanie do różnych intensywności pracy i zapewnia stałe nadciśnienie wewnątrz maski – nawet w okresach intensywnego oddychania – gwarantując niezrównaną ochronę. Co więcej, dmuchawa pracuje przy poziomie hałasu poniżej 65 dB, eliminując zakłócenia słuchowe i znacznie poprawiając komfort i koncentrację użytkownika podczas długich zmian. Jej główny silnik charakteryzuje się żywotnością ponad 50 000 godzin i został zaprojektowany tak, aby sprostać trudom częstego, intensywnego użytkowania przemysłowego oraz obniżyć koszty długoterminowej wymiany. Aparat PAPR BXH-3003 jest wyposażony w naukowo zaprojektowany, wysokowydajny, wielostopniowy system filtracji, który zapewnia warstwową ochronę czystego powietrza. Powietrze przepływa najpierw przez iskrochron i opcjonalny filtr wstępny, aby wychwycić duże cząstki stałe. Następnie można je połączyć z opcjonalnym filtrem wstępnym z węglem aktywnym, który pochłania zapachy i niektóre opary organiczne, a następnie jest ostatecznie oczyszczane przez filtr HEPA o skuteczności filtracji 99,97%, spełniający wymagania klasy TM3. Ta modułowa struktura filtracji nie tylko upraszcza konserwację i wymianę, ale także pozwala całemu systemowi PAPR elastycznie dostosowywać się do zróżnicowanych środowisk pracy, oferując niezawodną ochronę przed pyłem, oparami i aerozolami bakteryjnymi. Pod względem mocy i czasu pracy, defibrylator BXH-3003 PAPR jest zasilany dedykowaną baterią litową o pojemności 3400 mAh (25,16 Wh), zapewniającą wystarczającą wytrzymałość podczas dłuższej pracy. W zależności od ustawienia przepływu powietrza, czas pracy wynosi odpowiednio 11, 9 i 7 godzin, co w pełni pokrywa całą jedną zmianę roboczą. Akumulator pracuje przy napięciu znamionowym 7,4 V, ładuje się w zaledwie 2,5 godziny i zapewnia ponad 500 cykli ładowania i rozładowania, co zapewnia doskonałą trwałość. Dodatkowo, urządzenie posiada kompleksową funkcję alarmu systemowego: w przypadku niskiego poziomu naładowania akumulatora lub zatkania filtra (niski przepływ powietrza), aktywowane są alarmy dźwiękowe i wizualne (migające czerwone światło), które natychmiast informują użytkownika o konieczności wymiany filtra lub naładowania akumulatora, zapobiegając utracie ochrony z powodu awarii urządzenia.Konstrukcja respiratora BXH-3003 PAPR stawia na praktyczność i mobilność w zastosowaniach przemysłowych. Jednostka główna waży zaledwie 542 ± 10 g bez akumulatora i zaledwie 720 ± 10 g z zainstalowanym akumulatorem. W połączeniu z dedykowanymi uprzężami i wężem oddechowym, respirator ten minimalizuje obciążenie fizyczne użytkownika. Dzięki kompaktowym wymiarom 237 × 158 × 48 mm, respirator jest łatwy w przechowywaniu i transporcie. Modułowa konstrukcja systemu umożliwia szybki i beznarzędziowy demontaż i wymianę przedniej pokrywy, filtrów, akumulatora i innych komponentów, co znacznie zwiększa wydajność konserwacji na miejscu i zapewnia… system respiratora papr jest zawsze gotowy do użycia. Jako jednostka centralna całego systemu PAPR, dmuchawa BXH-3003 nie jest jedynie źródłem zasilania do oczyszczania powietrza – to niezawodne zabezpieczenie zapewniające użytkownikowi bezpieczne oddychanie. Doskonale łączy w sobie wysoką wydajność przepływu powietrza, wysokowydajną wielostopniową filtrację, stabilny czas pracy baterii i konstrukcję dostosowaną do potrzeb użytkownika, oferując profesjonalne rozwiązanie ochrony dróg oddechowych do szerokiego zakresu zastosowań, w tym w przemyśle produkcyjnym, budownictwie i służbie zdrowia. Dzięki BXH-3003 PAPR użytkownicy mogą pewnie pracować w środowiskach o wysokim poziomie zanieczyszczeń, nie martwiąc się o ryzyko narażenia na zanieczyszczenia. Aby dowiedzieć się więcej, kliknij tutaj. www.newairsafety.com.
    CZYTAJ WIĘCEJ

zostaw wiadomość

zostaw wiadomość
Jeśli jesteś zainteresowany naszymi produktami i chcesz poznać więcej szczegółów, zostaw wiadomość tutaj, a my odpowiemy tak szybko, jak to możliwe.
składać
KONTAKT: sales@txhyfh.com

Dom

Produkty

WhatsApp

Skontaktuj się z nami